ITINSP - Production inspection
|
Column
|
Required
|
Type
|
Precision
|
Description
|
OIDINTERFACE
|
X
|
TEXT
|
32
|
Sequential code - Identifies an item to be imported into SoftExpert Suite.
|
FGIMPORT
|
X
|
NUMERIC
|
2
|
Import status:
1 – New;
2 – In progress;
3 – Finished;
4 – Error.
|
CDISOSYSTEM
|
X
|
NUMERIC
|
10
|
System code where the integration will be performed to:
107 – PDM component code.
|
FGOPTION
|
X
|
NUMERIC
|
2
|
Code of the operation to be performed:
23 – Insert/Edit.
|
NMFIELD01
|
X
|
TEXT
|
255
|
Item ID #.
|
NMFIELD02
|
X
|
TEXT
|
255
|
Item revision #.
|
NMFIELD03
|
X
|
TEXT
|
255
|
Item characteristic ID #.
|
NMFIELD04
|
X
|
TEXT
|
255
|
Production inspection:
1 – Enabled;
2 – Disabled.
|
NMFIELD05
|
X1
|
TEXT
|
255
|
Sampling rule:
1 – Sampling plan;
3 – Defined size.
|
NMFIELD06
|
X2
|
TEXT
|
255
|
Sampling plan:
1 – Simple;
2 – Double;
3 – Multiple.
|
NMFIELD07
|
X2
|
TEXT
|
255
|
Inspection level:
1 – 01;
2 – 02;
3 – 03;
4 – S1;
5 – S2;
6 – S3;
7 – S4.
|
NMFIELD08
|
X2
|
TEXT
|
255
|
Work regime:
1 – Reduced;
2 – Normal;
3 – Multiple.
|
NMFIELD09
|
X2
|
TEXT
|
255
|
AQL:
1 – 0.01000000;
2 – 0.01500000;
3 – 0.02500000;
4 – 0.04000000;
5 – 0.65000000;
6 – 0.10000000;
7 – 0.15000000;
8 – 0.25000000;
9 – 0.40000000;
10 – 0.65000000;
11 – 1.00000000;
12 – 1.50000000;
13 – 2.50000000;
14 – 4.00000000;
15 – 6.50000000;
16 – 10.00000000;
17 – 15.00000000;
18 – 25.00000000;
19 – 40.00000000;
20 – 65.00000000;
21 – 100.00000000;
22 – 150.00000000;
23 – 250.00000000;
24 – 400.00000000;
25 – 650.00000000;
26 – 1000.00000000.
|
NMFIELD10
|
X3
|
TEXT
|
255
|
Number of samples.
|
NMFIELD11
|
|
TEXT
|
255
|
Unit of the number of samples.
|
NMFIELD12
|
X3
|
TEXT
|
255
|
Number of readings (Required in variable characteristics).
|
NMFIELD13
|
X3
|
TEXT
|
255
|
Number of items per sample (Required in attribute characteristics).
|
NMFIELD14
|
X3
|
TEXT
|
255
|
Maximum number of rejects (Required in attribute characteristics).
|
NMFIELD15
|
|
TEXT
|
255
|
Retest rule:
1 – Enabled;
2 – Disabled.
|
NMFIELD16
|
X4
|
TEXT
|
255
|
Retest result:
1 – Rejected;
2 – New retest.
|
NMFIELD17
|
X4
|
TEXT
|
255
|
Number of samples.
|
NMFIELD18
|
X4
|
TEXT
|
255
|
Unit of the number of samples.
|
NMFIELD19
|
X4
|
TEXT
|
255
|
Maximum number of rejects.
|
NMFIELD20
|
|
TEXT
|
255
|
Control time frequency:
1 – Enabled;
2 – Disabled.
|
NMFIELD21
|
X5
|
TEXT
|
255
|
Test frequency.
|
NMFIELD22
|
X5
|
TEXT
|
255
|
Unit:
5 – Minute(s);
6 – Hour(s).
|
NMFIELD23
|
|
TEXT
|
255
|
Test time.
|
NMFIELD24
|
X6
|
TEXT
|
255
|
Test time unit.
|
NMFIELD25
|
|
TEXT
|
255
|
Relative humidity.
|
NMFIELD26
|
X7
|
TEXT
|
255
|
Relative humidity unit.
|
NMFIELD27
|
|
TEXT
|
255
|
Test temperature.
|
NMFIELD28
|
X8
|
TEXT
|
255
|
Test temperature unit.
|
NMFIELD29
|
|
TEXT
|
255
|
Atmospheric pressure.
|
NMFIELD30
|
X9
|
TEXT
|
255
|
Atmospheric pressure unit.
|