This import template makes it possible to insert:
▪Asset meter readings
To insert each of these items, it is necessary to follow the standard documented below.
Insert reading
|
Column
|
Required
|
Type
|
Precision
|
Description
|
OIDINTERFACE
|
X
|
TEXT
|
32
|
Sequential code - Identifies an item to be imported into SoftExpert Suite.
|
FGIMPORT
|
X
|
NUMERIC
|
2
|
Import status:
1 – New;
2 – In progress;
3 – Finished;
4 – Error;
|
CDISOSYSTEM
|
X
|
NUMERIC
|
10
|
System code where the integration will be performed to:
126 – Code of the SoftExpert Maintenance component
|
FGOPTION
|
X
|
NUMERIC
|
2
|
Code of the operation to be performed:
2 – Insert meter reading
|
NMFIELD01
|
X
|
TEXT
|
255
|
Asset ID #.
|
NMFIELD02
|
X
|
TEXT
|
255
|
Action. List of options:
1 – New meter reading
2 – New meter restarter
|
NMFIELD03
|
X¹
|
TEXT
|
255
|
Reading value.
|
NMFIELD04
|
|
TEXT
|
255
|
Meter reading date.
If empty, it will consider the date and time of the import service.
|
NMFIELD05
|
X²
|
TEXT
|
255
|
Meter reading time, in the format hh:mm (00:00 - 23:59). If empty, it will consider the date and time of the import service.
|
|