Navigation:  Integration via database > Published interfaces > Maintenance >

MNPOINT - Calibration table point data import

Previous  Top  Next

This import template enables to edit:

Calibration table point data

 

To insert this item, it is necessary to follow the standard documented below.

Insert, edit, and delete Calibration data

Column

Required

Type

Precision

Description

OIDINTERFACE

X

TEXT

32

Sequential code - Identifies an item to be imported into SoftExpert Suite.

FGIMPORT

X

NUMERIC

2

Import status:

1 – New;

2 – In progress;

3 – Finished;

4 – Error.

CDISOSYSTEM

X

NUMERIC

10

System code where the integration will be performed to:

126 – Code of component SE Maintenance.

FGOPTION

X

NUMERIC

2

Code of the operation to be performed:

12 – Edit.

NMFIELD01

X

TEXT

255

Plan ID #.

NMFIELD02

X

TEXT

255

Certificate #.

NMFIELD03

X

TEXT

255

Calibration table name.

NMFIELD04

X

TEXT

255

Point name.

NMFIELD05

X1

TEXT

255

Indicates the point type:

1 – Rising point;

2 – Descent point.

NMFIELD06

X

TEXT

255

Indicates whether it is the case of a pre-calibration or calibration:

1 – Calibration;

2 – Pre-calibration.

NMFIELD07

X2

TEXT

255

Trend or systematic error value [Bias].

NMFIELD08

X2

TEXT

255

Total deviation value [Fges].

NMFIELD09

X2

TEXT

255

Deviation value [Fe].

NMFIELD10

X2

TEXT

255

Expanded uncertainty value [U95].

NMFIELD11

X2

TEXT

255

Ascending error value [Ascending error].

NMFIELD12

X2

TEXT

255

Descending error value [Descending error].

NMFIELD13

X2

TEXT

255

Range error value [Range error].

NMFIELD14

X2

TEXT

255

Average value [Average].

NMFIELD15

X2

TEXT

255

The highest reading value [The highest reading].

NMFIELD16

X2

TEXT

255

The lowest reading value [the lowest reading].

NMFIELD17

X2

TEXT

255

Hysteresis value [Hysteresis].

NMFIELD18

X2

TEXT

255

FT value [FT].

NMFIELD19

 

TEXT

255

Process ID #

NMFIELD20

X2

TEXT

255

Complementary variable.

Format: [variable ID #]=VALUE;

[variable ID #]=VALUE;

Example: g=9.81; UPAD=0.01.

NMFIELD21

 

TEXT

255

C.T.V. value.

 

X1 – Required in case of hysteresis.

X2 – Required if the variable is part of the formula.