Navigation:  Integration via database > Published interfaces > Inspection >

IPCFG - Inspection configuration

Previous  Top  Next

This import template enables to insert/edit/delete:

Inspection form data

 

To insert each of these items, it is necessary to follow the standard documented below.

Insert/edit

Column

Required

Type

Precision

Description

OIDINTERFACE

X

TEXT

32

Sequential code - Identifies an item to be imported into SoftExpert Suite.

FGIMPORT

X

NUMERIC

2

Import status:

1 – New;

2 – In progress;

3 – Finished;

4 – Error.

CDISOSYSTEM

X

NUMERIC

10

System code where the integration will be performed to:

34 – Code of component SoftExpert Inspection.

FGOPTION

X

NUMERIC

2

Code of the operation to be performed:

14 – Insert;

15 – Edit;

16 – Delete.

NMFIELD01

X1

TEXT

255

Inspection form type ID #.

NMFIELD02

X

TEXT

255

Inspection form ID #.

NMFIELD03

X1

TEXT

255

Item/Supply ID #.

NMFIELD04

X1

TEXT

255

Item/Supply revision ID #.

NMFIELD05

X1

TEXT

255

Process ID #

NMFIELD06

X1

TEXT

255

Process revision ID #.

NMFIELD07

X1

TEXT

255

Process activity ID #.

NMFIELD08

X2

TEXT

255

Evaluation group name.

NMFIELD09

X2

TEXT

255

Quality index ID #.

NMFIELD10

 

TEXT

255

Allow editing the receiving flow:

1 – Allow;

2 – Do not allow (default option).

NMFIELD11

X3

TEXT

255

Inspection flow ID #

NMFIELD12

 

TEXT

255

Block receiving for this inspection form:

1 – Block;

2 – Do not block (default option).

NMFIELD13

X4

TEXT

255

Frequency type:

1 – Uncontrolled;

2 – Execution date;

3 – Inspect an instance every... (only available when there are processes involved).

NMFIELD14

X5

TEXT

255

Frequency/Number of instances.

NMFIELD15

X5

TEXT

255

Frequency unit:

1 – Days;

2 – Weeks;

3 – Months;

4 – Years.

NMFIELD16

X5

TEXT

255

Date of the next execution.

NMFIELD17

X5

TEXT

255

Responsible team.

NMFIELD18

X6

TEXT

255

Inspection frequency.

NMFIELD19

X6

TEXT

255

Skip-lot type name.

NMFIELD20

X6

TEXT

255

Frequency sequence of the selected skip-lot.

NMFIELD21

 

TEXT

255

Control initial sample:

1 – Yes;

2 – No (default option).

NMFIELD22

X7

TEXT

255

Sample status:

1 – Blocked;

2 – Initial sample;

3 – Released.

NMFIELD23

X7

TEXT

255

Deadline.

NMFIELD24

 

TEXT

255

Control initial sampling validity:

1 – Yes;

2 – No (default option).

NMFIELD25

X8

TEXT

255

Initial sampling validity frequency.

NMFIELD26

X8

TEXT

255

Initial sampling validity frequency unit

1 – Days;

2 – Weeks;

3 – Months;

4 – Inspections.

DSFIELD01

 

TEXT

4000

Initial sampling comments.

NMFIELD27

X2

TEXT

255

Register averages/readings:

1 – Register averages;

2 – Register readings.

NMFIELD28

X9

TEXT

255

Rule:

1 – Sampling plan;

2 – Sampling table;

3 – Defined size;

4 – Percentage.

NMFIELD29

X9

TEXT

255

Sampling plan:

1 – Simple;

2 – Double;

3 – Multiple.

NMFIELD30

X9

TEXT

255

Inspection level:

The available options are the same as the values displayed on the inspection form data screen.

NMFIELD31

X9

TEXT

255

Work regime:

1 – Reduced;

2 – Normal;

3 – Tightened.

NMFIELD32

X9

TEXT

255

AQL:

The available options are the same as the values displayed on the inspection form data screen.

NMFIELD33

X9

TEXT

255

Sampling table ID #.

NMFIELD34

X9

TEXT

255

Sample size.

NMFIELD36

X9

TEXT

255

Number/Maximum percentage of rejects.

NMFIELD37

X9

TEXT

255

Percentage.

 

X1 – Required when adding; ignored for other actions

X2 – Mandatory when adding, optional while editing and deleting

X3 – Required if it does not allow editing the inspection flow

X4 – Required when adding if the form object type allows the frequency to be controlled

X5 – Required when adding if the frequency is controlled

X6 – Required when adding if the form object type requires the inspection frequency to be entered

X7 – Required when adding if the form object type requires the inspection frequency to be entered and the option to control the initial sample is active

X8 – Required when adding if the form object type requires the inspection frequency to be entered and the option to control the initial sample and the validity are active.

X9 – Required if the form object type requires filling out a sampling plan and the option of the sampling rule requires it to be filled in.