Navigation:  Integration via database > Published interfaces > Inspection >

IPCFGCAR - Characteristic relationship in inspection configuration

Previous  Top  Next

This import template enables to associate/edit/disassociate:

Inspection form characteristic data.

 

To insert each of these items, it is necessary to follow the standard documented below.

Insert/edit

Column

Required

Type

Precision

Description

OIDINTERFACE

X

TEXT

32

Sequential code - Identifies an item to be imported into SoftExpert Suite.

FGIMPORT

X

NUMERIC

2

Import status:

1 – New;

2 – In progress;

3 – Finished;

4 – Error.

CDISOSYSTEM

X

NUMERIC

10

System code where the integration will be performed to:

34 – Code of component SoftExpert Inspection.

FGOPTION

X

NUMERIC

2

Code of the operation to be performed:

20 – Insert characteristic;

21 – Edit characteristic;

22 – Delete characteristic.

NMFIELD01

X

TEXT

255

Inspection form ID #.

NMFIELD02

X

TEXT

255

Characteristic ID #.

NMFIELD03

 

TEXT

255

Required:

1 – Required (default option);

2 – Not required.

NMFIELD04

X1

TEXT

255

Validity.

NMFIELD05

X1

TEXT

255

Frequency unit:

1 – Days;

2 – Weeks;

3 – Months;

4 – Inspections.

NMFIELD06

 

TEXT

255

Add characteristic to the inspection report

1 – Yes;

2 – No (default option).

NMFIELD07

X2

TEXT

255

Register averages/readings:

1 – Register averages;

2 – Register readings.

NMFIELD08

X3

TEXT

255

Rule:

1 – Sampling plan;

2 – Sampling table;

3 – Defined size;

4 – Percentage.

NMFIELD09

X3

TEXT

255

Sampling plan:

1 – Simple;

2 – Double;

3 – Multiple.

NMFIELD10

X3

TEXT

255

Inspection level:

The available options are the same as the values displayed on the inspection form data screen.

NMFIELD11

X3

TEXT

255

Work regime:

1 – Reduced;

2 – Normal;

3 – Tightened.

NMFIELD12

X3

TEXT

255

AQL:

The available options are the same as the values displayed on the inspection form data screen.

NMFIELD13

X3

TEXT

255

Sampling table ID #.

NMFIELD14

X3

TEXT

255

Sample size.

NMFIELD16

X3

TEXT

255

Number/Maximum percentage of rejects.

NMFIELD17

X3

TEXT

255

Percentage.

 

X1 – Required when adding if the “Required” option is disabled.

X2 – Required when adding, optional while editing/deleting.

X3 – Required if the selected sampling type option requires filling the field in.