Navigation:  Integration via database > Published interfaces > Maintenance >

MNMAINTMETER – Meter reading

Previous  Top  Next

This import template makes it possible to insert:

Asset meter readings

 

To insert each of these items, it is necessary to follow the standard documented below.

Insert reading

Column

Required

Type

Precision

Description

OIDINTERFACE

X

TEXT

32

Sequential code - Identifies an item to be imported into SoftExpert Suite.

FGIMPORT

X

NUMERIC

2

Import status:

1 – New;

2 – In progress;

3 – Finished;

4 – Error;

CDISOSYSTEM

X

NUMERIC

10

System code where the integration will be performed to:

126 – Code of the SoftExpert Maintenance component

FGOPTION

X

NUMERIC

2

Code of the operation to be performed:

2 – Insert meter reading

NMFIELD01

X

TEXT

255

Asset ID #.

NMFIELD02

X

TEXT

255

Action. List of options:

1 – New meter reading
2 – New meter restarter

NMFIELD03

TEXT

255

Reading value.

NMFIELD04

 

TEXT

255

Meter reading date.

If empty, it will consider the date and time of the import service.

NMFIELD05

TEXT

255

Meter reading time, in the format hh:mm (00:00 - 23:59). If empty, it will consider the date and time of the import service.

 

X¹ - Required if the action is New meter reading. Not required if the action is New meter restart.

X¹ - Required if the reading date is filled in.