Navigation:  Integration via SOAP web services > Published web services > PDM >

relateProductionInspectionToChar

Previous  Top  Next

This method allows associating/editing:

Production inspection in item characteristic.

 

To insert each of these items, it is necessary to follow the standard documented below.

Java class

Request

web\wwwroot\ws\java\item\RelateProductionInspectionToCharRequestType.java

Return

web\wwwroot\ws\java\item\RelateProductionInspectionToCharResponseType.java

 

Request

ID #

Required

Description

IDOBJECT

X

Item ID #.

IDREVISION

X

Item revision #.

IDCHARACTERISTIC

X

Item characteristic ID #.

HASINSP

X

Production inspection:

1 – Enabled;

2 – Disabled.

FGSAMPLEPLAN

X1

Sampling rule:

1 – Sampling plan;  

3 – Defined size.

FGDEFAULTSAMPLEPLAN

X2

Sampling plan:

1 – Simple;

2 – Double;

3 – Multiple.

IDLEVEL

X2

Inspection level:

1 – 01;

2 – 02;

3 – 03;

4 – S1;

5 – S2;

6 – S3;

7 – S4.

FGSWITCHRULE_PLAN

X2

Work regime:

1 – Reduced;

2 – Normal;

3 – Multiple.

VLAQL

X2

AQL:

1 – 0.01000000;

2 – 0.01500000;

3 – 0.02500000;

4 – 0.04000000;

5 – 0.65000000;

6 – 0.10000000;

7 – 0.15000000;

8 – 0.25000000;

9 – 0.40000000;

10 – 0.65000000;

11 – 1.00000000;

12 – 1.50000000;

13 – 2.50000000;

14 – 4.00000000;

15 – 6.50000000;

16 – 10.00000000;

17 – 15.00000000;

18 – 25.00000000;

19 – 40.00000000;

20 – 65.00000000;

21 – 100.00000000;

22 – 150.00000000;

23 – 250.00000000;

24 – 400.00000000;

25 – 650.00000000;

26 – 1000.00000000.

QTSAMPLE

X3

Number of samples.

IDUNIDSAMPLE

 

Unit of the number of samples.

QTREADS

X3

Number of readings (Required in variable characteristics).

QTSAMPLEITEM

X3

Number of items per sample (Required in attribute characteristics).

QTACCEPTABLE

X3

Maximum number of rejects (Required in attribute characteristics).

FGUSERETEST

 

Retest rule:

1 – Enabled;

2 – Disabled.

FGRETESTRESULT

X4

Retest result:

1 – Rejected;

2 – New retest.

QTSAMPLERETEST

X4

Number of samples

IDUNIDSAMPLERETEST

X4

Unit of the number of samples.

QTACCEPTABLERETEST

X4

Maximum number of rejects.

FGUSEFREQUENCE

 

Control time frequency:

1 – Enabled

2 – Disabled.

QTFREQUENCY

X5

Test frequency.

FGFREQUENCY

X5

Unit:

5 – Minute(s);

6 – Hour(s).

QTTESTTIME

 

Test time.

IDUNIDTESTTIME

X6

Test time unit.

QTHUMITY

 

Relative humidity.

IDUNIDHUMITY

X7

Relative humidity unit.

VLTESTTEMP

 

Test temperature.

IDUNIDTESTTEMP

X8

Test temperature unit.

VLPRESSURE

 

Atmospheric pressure

IDUNIDPRESSURE

X9

Atmospheric pressure unit.

 

1 – Required when Production inspection is enabled.

2 – Required when Sampling rule is: Sampling plan.

3 – Required when Sampling rule is: Defined size.

4 - Required when Retest rule is enabled.

5 - Required when the option of controlling time frequency is enabled.

6 - Required when the Test time field is completed.

7 - Required when the Relative humidity field is completed.

8 - Required when the Test temperature field is completed.

9 - Required when the Atmospheric pressure field is completed.

 

Return

ID #

Description

return

SUCCESS: Return regarding the executed item

FAILURE: -1